Unit Sizes and Design Details

S.No UNIT SIZES DESIGN DETAILS BASED ON DESIGN FLOW
45 Boiler feed tank Dia 2.5m x 3.0 mHOS Capacity : 10KL Pump : 2 Nos4 m3/hr KW : 4 RPM : 2900.
46 Evaporator CIP Tank 4.0m * 3.2m * 3.5m Capacity : 30 m3 Pump : 1 Nos 60 m3/hr KW : 37 RPM : 3000
47 Boiler Capacity : 6 tons/hr Steam output : 4600 kg/hr Primary Forced Draft Fan Capacity 180 mm 1450 RPM 5.5 KW. Secondary Forced Draft Fan - 150mm 7.5KW 1475 RPM Induced Draft Fan : 1 Nos 30KW 1475 RPM Head @ 180c : 258 mmwc
48 Calendria - 1 Dia 1.6m x 11.3 mHOS Type : Falling film No of tubes : 514 Tube Size : 50.8Dia*9m Length Pump : Transfer Pump - 1 Flow : 220 m3/hr 22kw/1500 RPM
49 Calendria - 2 Dia 1.6m x 11.3 mHOS Type : Falling film No of tubes : 514 50.8mmDia*9m Length Pump : Transfer Pump - 2 220m3/hr/22 KW/1500 RPM
50 Calendria - 3 Dia 1.7m x 10.8 mHOS Type : Falling film No of tubes : 583 50.8mm Dia * 9m Length Pump : TP - 3 250m3/hr/30 KW/1000 RPM
51 Calendria - 4 Dia 1.2m x 11.1 mHOS Type : Falling film No of tubes : 316 50.8mm Dia*9m Length Pump TP - 4 150 m3/hr/22kw/1500 RPM
52 Calendria - 5 Dia 1.4m x 7.5 mHOS Type : Forced circulation No of tubes : 684 38.1mm Dia*6 m Length Tube Velocity : 1.8 - 1.9 m/sec Pump : 1 No. Recirculation Pump - 5 1800m3/hr/110KW/1000 RPM
53 Calendria - 6 Dia 1.4m x 7.5 mHOS Type : Forced circulation No of tubes : 684 38.1Dia*6 m Length Tube Velocity : 1.8 - 1.9 m/sec Pump RP - 6 1800m3/hr/132 KW /1000 RPM
54 Calendria - 7 Dia 1.3m x 7.3 mHOS Type : Forced circulation No of tubes : 540 38.1Dia*6 m Length Tube Velocity : 1.8 - 1.9 m/sec Pump RP - 7 1800m3/hr/132 KW / 1000 RPM
55 Surface Condenser Dia 0.9m x 10.2 mHOS Capacity : 45m3/hr Type : Forced circulation No. of tubes : 248 38.1 Dia x 9 m length
56 Vapour Separator - 1 Dia 1.5m x 4.3mHOS Type : Falling film
57 Vapour Separator - 2 Dia 1.5m x 4.3mHOS Type : Falling film
58 Vapour Separator - 3 Dia 1.5m x 4.3mHOS Type : Falling film
59 Vapour Separator - 4 Dia 1.1m x 3.3mHOS Type : Falling film
60 Vapour Separator - 5 Dia 2.0m x 6.5mHOS Type : Forced circulation
61 Vapour Separator - 6 Dia 2.0m x 6.5mHOS Type : Forced circulation
62 Vapour Separator - 7 Dia 2.2m x 6.5mHOS Type : Forced circulation
63 Air Compressor Make : Citizen Engg. Enterprises Model : TLS50C - 9E - 180L (5 HP) Pressure : 10 kg/cm2 Motor HP/KW : 5/3.7 KW RPM : 1050
64 Vacuum pump Make : PPI Systems Model : VWS - 650 C type Maximum Vacuum : 710 mm of Hg
65 Thermo Vapour Recompressor Make : Mazda Pressure : 0.62 bar (a)suction steam/9 bar(a) motive steam/ 1.15 bar (a) discharge
66 Pre Heater - 1 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
67 Pre Heater - 2 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
68 Pre Heater - 3 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
69 Pre Heater - 4 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
70 Pre Heater - 5 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
71 Pre Heater - 6 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
72 Pre Heater - 7 Dia 0.4m x 9.8mHOS Tube Size : 38.1mm Dia * 9m Length Tube Velocity : 1.8 - 1.9 m/sec
73 Pre Heater - 8 Dia 0.38m x 9.7mHOS Tube Size : 38.1mm Dia * 9m Tube Velocity : 1.8 - 1.9 m/sec Length
74 Mother liquid tank Dia 1.6m x 2.0mHOS Capacity : 45m3/hr Kw/ RPM : 5.5/1500
75 Cooling Tower water tank 6.0m*6.0m*1.3 m LD+0.5m FB Pump : 2 Nos 315m3/hr 37KW / 1500 RPM Product temp : 30 : 8
76 Sealing water tank Capacity : 200 lts pump : 1 No. 10 m3/hr/5.5kw/3000 RPM.
77 Pusher Centrifug Motor : 2 Nos Pusher Motor 1 : 15HP/1440 RPM Drive Motor 2 : 10HP/2800 RPM Feed Concentrate : 30 to 35% Moisture Content : 2 to 5%
78 Drain Tank (Evaporator) 2m * 1.5m * 1.5M LD Capacity : 4.5m3 Pump : 1 No. Flow Rate : 20 m3/hr Kw : 4.2 RPM : 2900